BSBSN - FLOWREX 100
- MSDS: BSBSN
- Manufacturer: MOBIL OIL CORP
- Product Name: FLOWREX 100
- National Stock Number: 9150-00N040836
Product Identification
Product ID:FLOWREX 100
MSDS Date:09/20/1987
FSC:9150
NIIN:00N040836
MSDS Number: BSBSN
Responsible Party
FAIRFAX, VA 22037
US
Emergency Phone: 212-883-4411;800-424-9300(CHEMTREC)
Info Phone: 703-849-3265
Cage: 1E969
Contractor
Telephone: 609-737-4411/800-424-9300(CHEMTREC)
Cage: 19135
Ingredients
REFINED MINERAL OILS
Fraction By Weight: 100%
OSHA PEL 5 MG/M3 (OIL MIST)
ACGIH TLV: 5 MG/M3 (OIL MIST)
BASE OILS IN THIS
RTECS: 9999999ZZ
TWO YEAR MOUSE SKIN PAINTING STUDIES OF SIMILAR OILS
RTECS: 9999999ZZ
REQ IMMED REPORTING OF SPILLS THAT COULD REACH
RTECS: 9999999ZZ
TO COAST GUARD TOLL FREE NUMBER 800-424-8802.
RTECS: 9999999ZZ
APPRVD WASTE DISP FACILITY. USE OF THESE
RTECS: 9999999ZZ
& LOCAL LAWS & REGULATIONS & CONSIDERATION OF PRODUCT
RTECS: 9999999ZZ
Hazards
LD50 LC50 Mixture:LD50:(ORAL,RAT) >5 G/KG.
Routes of Entry: Inhalation:NO Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:SLIGHT SKIN IRRIT. ACUTE:INGEST/SKIN
TOX:NONTOXIC - BASED ON TESTING OF SIM PRODS &/OR COMPONENTS.
INHAL:HARMFUL CONCS OF MISTS &/OR VAPS ARE UNLIKELY TO BE
ENCOUNTERED THRU ANY CUSTOMARY/REASONABLY F ORESEEABLE HNDLG,
USE/MISUSE OF PROD. EYE:EXPECTED TO NON-IRRIT. BASED ON TESTING OF
SIM PRODS &/OR (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:COMPONENTS. SKIN IRRIT:MAY CAUSE
SLIGHT IRRIT ON PRLNG/RPTD CONT. BASED ON TESTING OF SIM PRODS &/OR
COMPONENTS. SUBCHRONIC:SEVERELY SOLV REFINED & SEVERELY
HYDROTREATED MINERAL BASE OILS HAV E BEEN TESTED @ MOBIL ENVIRON &
HLTH SCIENCES LAB BY DERMAL APPLICATION TO RATS 5 DAYS/WK FOR 90
DAYS @ DOSES (SUPDAT)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
First Aid
First Aid:INHAL:REMOVE TO FRESH AIR. SUPPORT BREATHING (GIVE O*2/ARTF
RESP) . EYES:FLUSH W/WATER FOR AT LEAST 15 MINUTES. SKIN:WASH
CONTACT AREAS W/SOAP & WATER. INGEST:NOT EXPECTED TO BE A PROBLEM.
IF UN COMFORTABLE SEEK MEDICAL ASSISTANCE.
Fire Fighting
Flash Point Method:COC
Flash Point:>300F,>149C
Lower Limits:0.6%
Upper Limits:7%
Extinguishing Media:CARBON DIOXIDE, FOAM, DRY CHEMICAL & WATER FOG.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP
. WATER/FOAM MAY CAUSE FROTHING. USE WATER TO KEEP FIRE EXPOSED
CNTNRS COOL. WATER SPRAY MAY BE USED(SUPDAT)
Unusual Fire/Explosion Hazard:NONE
Accidental Release
Spill Release Procedures:ABSORB ON FIRE RETARDANT TREATED SAWDUST,
DIATOMACEOUS EARTH, ETC. SHOVEL UP & DISP OF @ APPROP WASTE DISP
FACILITY I/A/W CURRENT APPLIC LAWS & REGS, & PROD CHARACTS @ TIME
OF DISP. REPORT SPILLS AS R EQD TO APPROP AUTHS. U.S. COAST GUARD
REGS (ING 4)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:NO SPECIAL PRECAUTIONS REQUIRED.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.
Exposure Controls
Respiratory Protection:USE NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE
FOR EXPOSURE OF CONCERN . NO SPECIAL REQUIREMENTS UNDER ORDINARY
CONDITIONS OF USE & W/ADEQUATE VENTILATION.
Ventilation:NO SPECIAL REQUIREMENTS UNDER ORDINARY CONDITIONS OF USE &
W/ADEQUATE VENTILATION.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APRV CHEMICAL WORKERS GOGGLES (FP N
Other Protective Equipment:NO SPECIAL EQUIPMENT REQUIRED.
Work Hygienic Practices:GOOD PERSONAL HYGIENE PRACTICES SHOULD ALWAYS
BE FOLLOWED.
Supplemental Safety and Health
FIRE FIGHT PROC:TO FLUSH SPILLS AWAY FROM EXPOS. PVNT RUN-OFF FROM FIRE
CTL/POLLUTION FROM ENTERING STREAMS/DRINKING WATER SUPPLY. EFTS OF
OVEREXP:SIGNIFICANTLY HIGHER THAN THOSE EXPECTED DURING NORMA L
INDUS EXPOS. EXTENSIVE EVALS INCL MICROSCOPIC EXAM OF INTERNAL
ORGANS & CLINICAL CHEMISTRY OF BODY FLUIDS, (ING 2)
Chemical Properties
Boiling Pt:B.P. Text:>600F,>316C
Vapor Pres:<0.1 @ 20C
Solubility in Water:NEGLIGIBLE
Appearance and Odor:ASTM 3.5 LIQUID; MILD ODOR.
Stability
Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZERS.
Stability Condition to Avoid:EXTREME HEAT.
Hazardous Decomposition Products:CARBON MONOXIDE.
Disposal
Waste Disposal Methods:PROD IS SUITABLE FOR BURNING IN ENCLSD,
CONTROLLED BURNER FOR FUEL VALUE/DISP BY SUPERVISED INCIN. SUCH
BURNING MAY BE LTD PURSUANT TO RCRA. IN ADDN, PROD IS SUITABLE FOR
PROCESSING BY APPRVD RECYCLIN G FACILITY/CAN BE DISP OF @ ANY GOVT
(ING 6)
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.